(Prescribed under Schedule – H (v), H (xxx) and H (xxxi) to Rule - 66)
[Report of Examination and Test of Dust Extraction of Supersession System]
1 Description of system
2 Hood-
(a) Serial number of hood
(b) Contaminant captured
(c) Capture Velocities (at points to be specified)
Design Value Actual Value
(d) Volume exhausted at hood
(e) Hood Static Pressure
3 Total Pressure drop at--
(a) Joints
(b) Other points of system (to be specified)
4 Transport velocity in duct at points along ducts (to be specified)
5 Air cleaning device--
(a) Type used
(b) Velocity at inlet
(c) Static pressure at inlet
(d) Velocity at outlet
(e) Static Pressure at outlet
6 Fan-
(a) Type used
(b) Volume handled
(c) Static Pressure
(d) Pressure drop at outlet of fan
7 Fan Motor-
(a) Type
(b) Speed and power in kilowatts
Particulars of defects, if any, disclosed during
8
test of any of the above components
I certify that on (date ............................................) the above dust extraction system was
thoroughly cleaned and so far as its construction permits made available for thorough examination. I
further certify that on the said date, I thoroughly examined the above dust extraction system including
its components and fittings and that the above is a true report of my examination.
Signature .....................
Qualification .................
Address .......................
Date ..........................
If employed by a company or association, name and address of the company or association.