Compression of oxygen and hydrogen produced by electrolysis of water
1. Location of electrolyte plant.—The room in which electrolysis plant is installed
shall be separate from the plant for storing and compressing the oxygen and
hydrogen and also the electric generator room.
2. Testing of purity.-
I. The purity of oxygen and hydrogen shall be tested by a competent
person at least once in every shift at the following posts :-
a. in the electrolysis room ;
b. at the gas holder inlet ; and
c. at the suction and of the compressor.
II. The purity figures shall be entered in a register and signed by the
persons carrying out such test :
Provided, however, that if the electrolysis plant is fitted with automatic
recorder of purity of oxygen and hydrogen with alarm lights, it shall be
sufficient if the purity of gases is tested at the suction and of the
compressor only.
3. Restriction as to the compression.-The oxygen and hydrogen gases shall
not be compressed if their purity as determined under paragraph 2 above falls
below 98% at any time.
4. Limit switch for gas holder.—The bell of any gas holder shall not be
permitted to go within the 30 centimetres of its lowest position when empty
and a limit switch shall be fitted to the gas holder in such a manner as to
switch off the compressor motor when the limit is reached.
5. Provision of negative pressure switch.—In addition to the limit switch in
the gas holder, a sensitive negative pressure switch shall be provided in or
adjacent to the suction main for hydrogen close to the gas holder and
between the gas holder and the hydrogen compressor to switch off the
compressor motor in the event of the gas holder being emptied to the extent
as to cause vacuum.
6. Purity of caustic soda.—The water and caustic soda used for making lye
shall be chemically pure within pharmaceutical limits.
7. Precautions against reversal of polarity.-Electrical connections at the
electrolyser cells and at the electric generator terminals shall be
SO
constructed as to preclude the possibility of wrong connections leading to the
reversal of polarity and in addition an automatic device shall be provided to
cut off power in the event of reversal of polarity owing to wrong connections
either at the switch board or at the electric generator terminals.
8. Colouring of gas pipes.-Oxygen and hydrogen gas pipes shall be painted
with distinguishing colours and in the event of leakage at the joints of the
hydrogen gas pipe, the pipe after reconnection shall be purged of all air
before drawing in hydrogen gas.
9. Use of flameproof fittings.-All electrical wiring and apparatus in the
electrolyser room shall be of flameproof construction or enclosed in
flameproof fittings and no naked light or flame shall be allowed to be taken
either in the electrolyser room or where compression and filling of the gases
is carried on and such warning notices shall be exhibited in prominent places.
10. Prohibition of hot work.-No part of the electrolyser plant and the gas
holders and compressor shall be subjected to welding, brazing, soldering or
cutting until steps have been taken to remove any explosive substance from
that part and render the part safe for such operations and after the
completion of such operations no explosive substance shall be allowed to
enter that part until the metal has cooled sufficiently to prevent risk of
explosion.
11. Repair, etc. to be done under supervision.—No work or operations,
repair or maintenance shall be undertaken except under the direct supervision
of a person who, by his training, experience and knowledge of the necessary
precautions against risk of explosion is competent to supervise such work. No
electric generator after erection or repairs shall be switched on/the
electrolysers unless the same is certified by the competent persons under
whose direct supervision erection or repairs are carried on to be in a safe
condition and the terminals have been checked for the polarity as required by
paragraph 7.
12. Checking of plant.-Every part of the electrolysis plant and the gas holders
and compressor shall have a regular schedule of overhaul and checking and
every defect noticed shall be rectified forthwith.